REGULATED HIGH VOLTAGE MODULE FOR XRF APPLICATION

TECHNICAL SPECIFICATIONS

PARAMETER SPECIFICATION
Input Voltage 24V DC ± 10%
Output Voltage* 0 to 10/20/30/40/50kV DC
Output Current 0 to 1mA
Polarity * Positive / Negative
Line Regulation <0.05% for±10% variation in input voltage
Load Regulation <0.1% for 10 to 100%load variation
Stability <0.01%hour after 1 hour warm up
Protections Against overload, arc and short-circuit
During short circuit, internal circuitry limits the short circuit current
Front Panel 24V DC input through 1.0sqm PVC wires
Fuse holder with fuse (on top plate)
RF connector for HV output
9 pin D-connector for remote control
Stud for grounding the unit
Size 5” x 9” x 3” (W x D x H)
Weight 2.5kg
Output cable 26” of HV DC cable

Remote Interface Connector Configuration

Pins 28 Pin Pluggable Connector
1 Common
2 HV Enable (Active Low)
3 Voltage Program
4 Voltage Monitor
5 Current Program
6 Current Monitor
7 Reserved
7 Reserved
7 +10V DC Reference

Ordering Code
MF 050 K 050 W P C 2 D 4 L

Section Description Options Options Description
1 Output Voltage XX Value of output voltage XX=10/20/30/40/50: For 10/20/30/40/50kV
2 Output Power YY Value of output power (XX x 1mA) YY=10/20/30/40/50W
3 Polarity P
N
Positive
Negative