PARAMETER |
SPECIFICATION |
Input Voltage |
230V ±10% A C, 50Hz, Single Phase for output power ≤ 2kW
415V ±10% A C, 50Hz, three Phase for output power > 2kW |
Output Voltage Range* |
10V to 100V AC (variable), single phase, 50Hz, sine wave |
Output Power Range* |
50W to 5kW |
DC Isolation* |
10kV to 150kV DC |
Output Waveform |
Sine wave floating on high voltage DC isolation |
Type of Primary Control |
Linear (sine wave) |
Line Regulation |
1% for 10% variation in input voltage |
Load Regulation |
±1% for 0 to 100% load variation |
Regulating Mode |
Constant voltage or constant current selectable through a selector switch in front panel at ground level |
Leakage Current Through Transformer Secondary to Ground & Primary |
< 200µA |
Rate of Rise of Floating AC Voltage* |
1V/second to 1V/ minute |
Current Sensing |
Through load floating on DC isolation |
Protections |
Against over load, short-circuit and arc
During short circuit, power supply trips & to be manually reset to restart |
Mode of Operation |
Local or remote selectable through a selector switch in front panel at ground level |
Front Panel |
Power ON/OFF switch with indication
Push buttons for power supply start & stop
Rotary push switch for emergency trip
Push button for trip reset
3½ dig it rms voltage and rms current meters
10-turn potentiometer for voltage rise control
10-turn potentiometers for over voltage & over current trip level setting
Selector switch for Local / Remote selection
Selector switch for regulating mode selection
Constant voltage – constant current mode indication |
Back Panel |
Socket for mains input with 250V, 20A 3 conductor power cord of 1.5 meters / terminal block for 3 phase input
Fuse holder with fuse
Pluggable connectors for remote control
stud for grounding the unit |
Remote Controls & Signals (all at ground level) |
Power supply ON/OFF
Reference 10V DC signal
0-10V DC for voltage rise control
0-10V DC FSD for rms voltage monitor
0-10VDC FSD for rms current monitor |
Cabinet |
MS cabinet with wheels, powder coated |