MONOBLOCKS FOR NDT

125kV / 160kV / 220kV, 5mA

This series of high-frequency power supplies, designed for continuous NDT inspection, are available in 125kV, 160kV, and 220kV models, each with a 5mA output. Compact and reliable, they connect to X-Ray tubes for superior imaging and better evaluation. Ideal for OEM applications.

TECHNICAL SPECIFICATIONS

PARAMETER SPECIFICATION
Input Voltage 230V ±10% AC, 50Hz, single phase
No. of Output 2
Output Voltage 1
125kV 160kV 220kV
0 to +62.5kV DC 0 to +80kV DC 0 to +110kV DC
Output Voltage 2
0 to -62.5kV DC 0 to -80kV DC 0 to -110kV DC
Output Current 0 to 5mA
HF Generator Frequency 40kHz
Filament Voltage and Current As per tube selection by OEM
Polarity Positive and negative
Protections Over voltage, over current, filament open fault, short-circuit, and arc
Line Regulation <0.1% for 10% variation in input voltage
Load Regulation <0.5% for 10% load variation (tube current)
Mode of Operation Constant voltage-constant & current (X-ray anode current)
0-10VDC Signals from PLC to Power Supply Output voltage control
Output current control
0-24V DC Signals from PLC to Power Supply Selection of HV ON/OFF, small / large filament, rotor start / stop
0-10VDC Signals from Power Supply PLC Output voltage readout
Output current readout
Rotating Anode Circuit Based on 24VDC signals from the PLC, control the rotor supply 160V for 0.8sec and 40V for running till the presence of the 24V DC
Topology SMPS
Cable and Connectors To be supplied by the OEM
HT Tank
125kV 160kV 220kV
MS Tank
475mm × 310mm × 243mm
MS Tank
550mm × 320mm × 248mm
MS Tank
650mm × 400mm × 753mm
Inverter 19” Rack (440mm × 458mm × 142mm)
+91 89198 44858 Call Sales
marketing@ionics.co.in Reach out to us @
+91 99853 01016 Call Support